Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download BibTeX

Title

PCM-Filled Capsules (RT44HC) for Heat Storage - Laboratory Scale Pilot Study

Authors

[ 1 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Year of publication

2025

Published in

Energies

Journal year: 2025 | Journal volume: vol. 18 | Journal number: iss. 2

Article type

scientific article

Publication language

english

Keywords
EN
  • PCM
  • heat storage
  • RT44HC
  • district heating
  • heat accumulation
Abstract

EN Peak power shaving in heating systems can be achieved using heat accumulators, traditionally implemented in the form of water storage tanks. Their heat capacity can be increased by using a phase change material (PCM) instead of water, which, however, usually requires a change in the tank design. The innovation of this paper is an interesting concept to use plastic capsules filled with a PCM that replace part of the water volume in an existing heat accumulator. The aim of this paper is to compare the cooling rate of the same volume of water as that of the water mixed with the PCM capsules to initially verify the heat storage potential of the capsules. The results of pilot experimental studies on a laboratory scale are presented and discussed, showing the potential of this idea for heat storage. The partial replacement of water with capsules (40% of the total volume) results in significantly faster heat accumulation with the same tank volume (3.85 times at the beginning of the process) and more heat stored (decrease in the temperature of water alone by 14 K and water with PCM capsules by 26 K in the same period of time), which gives promising perspectives for the use of this solution on a semitechnical scale and further in a real-size heating system.

Date of online publication

14.01.2025

Pages (from - to)

345-1 - 345-16

DOI

10.3390/en18020345

URL

https://www.mdpi.com/1996-1073/18/2/345

Comments

Article Number: 345

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Ministry points / journal

140

Impact Factor

3 [List 2023]

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.