Improved methodology to survey veterinary antibiotics in environmental samples using µSPEed microextraction followed by ultraperformance liquid chromatography

Authors

[ 1 ] Department of Water Supply and Bioeconomy, Faculty of Environmental Engineering and Energy, Poznan University of Technology, Berdychowo 4, 60-965 Poznan, Poland | [ 2 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ 3 ] Instytut Chemii i Elektrochemii Technicznej, Wydział Technologii Chemicznej, Politechnika Poznańska | [ SzD ] doctoral school student | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy
[7.6] Chemical sciences

Year of publication

2025

Published in

Communications Chemistry

Journal year: 2025 | Journal volume: vol. 8

Article type

scientific article

Publication language

english

Keywords
EN
  • µSPEed microextraction
  • Veterinary antibiotics
  • Environmental water
  • Food chain surveillance
  • Liquid chromatography
  • Tetracyclines
Abstract

EN A μSPEed microextraction combined with ultra-performance liquid chromatography (UHPLC) with UV detection was developed for analysing six veterinary antibiotics (tetracycline, chlortetracycline, oxytetracycline, doxycycline, sulfamethoxazole, and trimethoprim) in environmental samples. To optimise extraction, 12 sorbent cartridges, sample loading cycles, volumes, and pH were assayed. The PS/DVB-RP cartridge, three 250 μL sample loading cycles, and two 50-µL elutions with acidified methanol yielded maximum efficiency. The method was validated with optimised fast chromatographic separation, showing good linearity (R2 > 0.99), precision (RSD < 20%), and recoveries between 46-86%. Detection and quantification limits ranged from 0.30-1.23 μg L−1 and 0.92-3.73 μg L−1, respectively. The optimised μSPEed/UPLC-PDA efficiently analysed environmental water samples, requiring only 6 min extraction, 6 min analysis, and 500 μL sample, surpassing alternative methods in speed, workloads and reproducibility. The cost-effective, commercially available equipment facilitates accessibility for laboratories and adaptability for analysing selected antibiotics in diverse matrices, including food and environmental samples.

Date of online publication

08.03.2025

Pages (from - to)

68-1 - 68-8

DOI

10.1038/s42004-025-01454-w

URL

https://www.nature.com/articles/s42004-025-01454-w

Comments

Article Number: 68

License type

CC BY-NC-ND (attribution - noncommercial - no derivatives)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Ministry points / journal

20

Impact Factor

6,2 [List 2024]

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.