Wpływ temperatury złącza diod elektroluminescencyjnych na ich parametry elektryczne i optyczne

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Automatyki, Robotyki i Elektrotechniki, Politechnika Poznańska | [ 2 ] Instytut Elektroenergetyki, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.2] Automation, electronics, electrical engineering and space technologies

Title variant

EN The influence of the junction temperature of light-emitting diodes on their electrical and optical parameters

Year of publication

2025

Chapter type

chapter in monograph / paper

Publication language

polish

Abstract

PL W artykule przedstawiono podstawowe parametry elektryczne i optyczne diod elektroluminescencyjnych oraz wpływ temperatury złącza na ich wartości. Zaprezentowano metodykę przeprowadzania pomiaru umożliwiającego wiarygodną ocenę temperatury złącza oraz wykorzystaną podczas badań aparaturę. Przedstawiono rezultaty prac badawczych przeprowadzonych z wykorzystaniem komory termicznej, wyniki pomiarów wybranych parametrów elektrycznych i optycznych uzyskane w normalnych warunkach pracy oraz wyznaczone metodą elektryczną wartości temperatury złącza. Badania przeprowadzono dla wybranych pasków LED, zabudowanych w osłonie silikonowej oraz pozbawionych tej osłony.

EN The article presents the basic electrical and optical parameters of light-emitting diodes and the influence of junction temperature on their values. The methodology for conducting measurements enabling reliable assessment of junction temperature and the apparatus used during the tests are presented. The results of research work conducted using a thermal chamber, measurement results of selected electrical and optical parameters obtained under normal operating conditions and junction temperature values determined by the electrical method are presented. The tests were carried out for selected LED strips, with and without a silicone cover.

Date of online publication

22.09.2025

Pages (from - to)

119 - 134

DOI

10.21008/b.978-83-7775-811-3.9

Book

MKM 2025, LVII Międzyuczelniana Konferencja Metrologów. Materiały Konferencyjne

Presented on

LVII Międzyuczelniana Konferencja Metrologów, MKM 2025, 22-24.09.2025, Poznań, Polska

License type

CC BY-SA (attribution - share alike)

Open Access Mode

open repository

Open Access Text Version

final published version

Release date

22.09.2025

Date of Open Access to the publication

at the time of publication

Full text of chapter

Download file

Access level to full text

public

Ministry points / chapter

20

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.