Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Chapter

Download BibTeX

Title

Comparison of Fault Tolerant Control Algorithm Using Space Vector Modulation of PMSM Drive

Authors

[ 1 ] Instytut Automatyki i Inżynierii Informatycznej, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Year of publication

2014

Chapter type

paper

Publication language

english

Keywords
EN
  • fault tolerant control
  • space vector modulation
  • 4-switch 3-phase inverter
  • SVPWM
  • PMSM
Abstract

EN This paper presents developed compact algorithms of space vector pulse width modulation (SVPWM) for six-switch and four-switch three-phase inverter. Calculations of the desired voltage vector in the PMSM drive are presented, an optimal voltage vector sequence and scaling factors for SVM has been derived to synthesize the reference voltage vector in each sampling period for healthy and fault drive. It has been proved by simulation and experimental results that four-switch inverter fed PMSM is able to operate steadily and with very good static and dynamic properties under the proposed SVPWM approach.

Pages (from - to)

24 - 31

DOI

10.1109/MECHATRONIKA.2014.7018231

URL

https://ieeexplore.ieee.org/document/7018231

Book

16th Mechatronika 2014 : Proceedings od 16th International Conference on Mechatronics : Mechatronika 2014

Presented on

16th International Conference on Mechatronics - Mechatronika (ME) 2014, 3-5.12.2014, Brno, Czech Republic

Publication indexed in

WoS (15)