Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download BibTeX

Title

Time effective methods of calculation of maximum time interval error

Authors

[ 1 ] Instytut Elektroniki i Telekomunikacji (IEt), Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Year of publication

2001

Published in

IEEE Transactions on Instrumentation and Measurement

Journal year: 2001 | Journal volume: vol. 50 | Journal number: iss. 3

Article type

scientific article

Publication language

english

Keywords
EN
  • computing
  • effectiveness
  • synchronization
  • telecommunication network
  • time error
  • time interval
  • timing signal
Abstract

EN In this paper, the time effective calculation methods of the maximum time interval error estimate (MT/spl circ/IE) are proposed. The formula of the MTIE estimator and the time error sequence measurement conditions are presented. The method of MT/spl circ/IE calculation based directly on the estimator's definition is the first method presented. Then the methods which enable computation of the MTIE estimate in a rather short time are proposed. The experiment of MT/spl circ/IE calculation using the presented method is described. The comparison between the methods is made. The pros and cons of the proposed methods are pointed out.

Pages (from - to)

732 - 741

DOI

10.1109/19.930447

URL

https://ieeexplore.ieee.org/document/930447