Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Chapter

Download BibTeX

Title

Experimental Verification of Metrological Properties of Power Quality Analyser

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Year of publication

2015

Chapter type

paper

Publication language

english

Keywords
EN
  • harmonics
  • Fourier series
  • uncertainty budget
Abstract

EN Electrical power quality assessment is a complex measurement task, requiring the usage of a system with suitable metrological properties. The parameters dedicated to assess the power quality are measured and registered with the use of measurement devices called power quality analysers. Examples of the results of testing a selected power quality analyser in a designed measuring system are presented in the paper. The measurement results were completed with a presentation of the uncertainty budget.