A Method for the Determination of Thermal Time Constant of Pyroelectric Sensor from Voltage Response to Step Optical Input Signal

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Year of publication

2015

Chapter type

paper

Publication language

english

Keywords
EN
  • pyroelectric sensor
  • responsivity
  • thermal time constant of pyroelectric sensor
Abstract

EN A method for measuring of the thermal time constant of pyroelectric sensor using the voltage response to a step optical input signal is proposed. An important advantage of this method over the traditional one is, that to get a correct result of the thermal time constant measurement it is no longer required that the thermal and electric time constants should be significantly different.