Application of Experimental Studies of Humidity and Temperature in the Time Domain to Determine the Physical Characteristics of a Perlite Concrete Partition

Autorzy

[ 1 ] Instytut Budownictwa, Wydział Inżynierii Lądowej i Transportu, Politechnika Poznańska | [ P ] pracownik

Dyscyplina naukowa (Ustawa 2.0)

[2.7] Inżynieria lądowa, geodezja i transport

Rok publikacji

2024

Opublikowano w

Materials

Rocznik: 2024 | Tom: vol. 17 | Numer: iss. 19

Typ artykułu

artykuł naukowy

Język publikacji

angielski

Słowa kluczowe
EN
  • perlite concrete
  • thermal conductivity coefficient
  • sustainable construction
  • homogeneous partitions
  • hygrothermal performance
  • humidity of perlite
  • heat transfer
  • single-layer wall
Streszczenie

EN These days, the use of natural materials is required for sustainable and consequently plus-, zero- and low-energy construction. One of the main objectives of this research was to demonstrate that pelite concrete block masonry can be a structural and thermal insulation material. In order to determine the actual thermal insulation parameters of the building partition, in situ experimental research was carried out in real conditions, taking into account the temperature distribution at different heights of the partition. Empirical measurements were made at five designated heights of the partition with temperature and humidity parameters varying over time. The described experiment was intended to verify the technical parameters of perlite concrete in terms of its thermal insulation properties as a construction material used for vertical partitions. It was shown on the basis of the results obtained that the masonry made of perlite concrete blocks with dimensions of 24 × 24.5 × 37.5 cm laid on the mounting foam can be treated as a building element that meets both the structural and thermal insulation requirements of vertical single-layer partitions. However, it is important for the material to work in a dry environment, since, as shown, a wet perlite block has twice the thermal conductivity coefficient. The results of the measurements were confirmed, for they were known from the physics of buildings, the general principles of the formation of heat and the moisture flow in the analysed masonry of a perlite block. Illustrating this regularity is shown from the course of temperature and moisture in the walls. The proposed new building material is an alternative to walls with a layer of thermal insulation made of materials such as polystyrene or wool and fits into the concept of sustainable construction, acting against climate change, reducing building operating costs, improving living and working conditions as well as fulfilling international obligations regarding environmental goals.

Data udostępnienia online

09.10.2024

Strony (od-do)

4938-1 - 4938-21

DOI

10.3390/ma17194938

URL

https://www.mdpi.com/1996-1944/17/19/4938

Uwagi

Article Number: 4938

Typ licencji

CC BY (uznanie autorstwa)

Tryb otwartego dostępu

otwarte czasopismo

Wersja tekstu w otwartym dostępie

ostateczna wersja opublikowana

Czas udostępnienia publikacji w sposób otwarty

w momencie opublikowania

Punktacja Ministerstwa / czasopismo

140

Impact Factor

3,1 [Lista 2023]

Ta strona używa plików Cookies, w celu zapamiętania uwierzytelnionej sesji użytkownika. Aby dowiedzieć się więcej przeczytaj o plikach Cookies i Polityce Prywatności.