Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Dissertation

Download BibTeX

Title

Analiza i sterowanie napędem PMSM zasilanym z bezpośredniego przekształtnika matrycowego typu Quasi-Z-Source

Authors

[ 1 ] Instytut Robotyki i Inteligencji Maszynowej, Wydział Automatyki, Robotyki i Elektrotechniki, Politechnika Poznańska | [ P ] employee

Promoter

[ 1 ] Instytut Robotyki i Inteligencji Maszynowej, Wydział Automatyki, Robotyki i Elektrotechniki, Politechnika Poznańska | [ P ] employee

Reviewers

Title variant

EN Analysis and control of PMSM drive fed by Quasi-Z-Source direct matrix converter

Language

polish

Keywords
PL
  • silnik synchroniczny o magnesach trwałych
  • bezpośredni przekształtnik matrycowy typu quasi-z-source
  • zapady napięcia
  • regulacja prędkości
  • odporność na uszkodzenia
EN
  • permanent magnet synchronous motor
  • quasi z-source direct matrix converter
  • voltage sag
  • speed control
  • fault tolerance
Abstract

PL W pracy zaproponowano system sterowania napędu z PMSM zasilanego z bezpośredniego przekształtnika typu Quasi-Z-Source (QZS) jako metodę zwiększenia odporności maszyny na zapady napięcia w sieci. Przedstawiono strukturę i algorytmy regulacji umożliwiające sterowanie napięciem wyjściowym z przekształtnika. Metody te oparte są na transformacji dq, która zapewnia sygnał pomiarowy dla regulatora typu PI. W rozprawie opracowano model symulacyjny w Matlabie, który umożliwił wstępną weryfikację struktur i metod. Model ten wykazał istnienie nieliniowości w układzie sterowania napięciem QZS. Opisano również stworzone na potrzeby pracy stanowisko laboratoryjne, które umożliwiło eksperymentalną weryfikację wiedzy zdobytej w części symulacyjnej. Zweryfikowano prawidłową pracę napędu z zaproponowanym systemem sterowania oraz jego nieliniowość w pętli regulacji napięcia QZS. Przeprowadzone badania wykazały poprawne działanie napędu oraz jego zwiększoną odporność na zapady napięcia sieciowego.

EN In this paper, a control system for a PMSM powered by a Quasi-Z-Source (QZS) direct matrix converter is proposed as a method to increase the machine's resistance to voltage sags in the power grid. The structure and control algorithms presented enable the control of the converter's output voltage. These methods are based on the dq transformation, providing a measurement signal for a PI controller. A simulation model developed in Matlab allowed for verification of the control structure and methods. This model demonstrated the presence of nonlinearity in the QZS voltage control system. Additionally, a laboratory stand was created for the experimental verification of the knowledge gained from the simulation part of the work. The proper operation of the drive with the proposed control system and its nonlinearity in the QZS voltage control loop were verified. The conducted studies confirmed the correct operation of the drive and its increased resistance to voltage sags in the power grid.

Number of pages

141

Scientific discipline (Law 2.0)

automation, electronics, electrical engineering and space technologies

Signature of printed version

DrOIN 2386

On-line catalog

to2024233122

Full text of dissertation

Download file

Access level to full text

public

First review

Marcin Morawiec

Place

Gdańsk, Polska

Date

26.08.2024

Language

polish

Review text

Download file

Access level to review text

public

Second review

Andrzej Sikorski

Place

Białystok, Polska

Date

16.08.2024

Language

polish

Review text

Download file

Access level to review text

public

Dissertation status

dissertation

Place of defense

Poznań, Polska

Date of defense

22.10.2024

Unit granting title

Rada Dyscypliny Automatyka, Elektronika, Elektrotechnika i Technologie Kosmiczne Politechniki Poznańskiej

Obtained title

doktor nauk inżynieryjno-technicznych w dyscyplinie: automatyka, elektronika, elektrotechnika i technologie kosmiczne