Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Chapter

Download BibTeX

Title

Detection of Wet Age-related Macular Degeneration in OCT Images: A Case Study

Authors

[ 1 ] Instytut Informatyki, Wydział Informatyki i Telekomunikacji, Politechnika Poznańska | [ 2 ] Instytut Informatyki, Wydział Informatyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.3] Information and communication technology

Year of publication

2018

Chapter type

chapter in monograph / paper

Publication language

english

Keywords
EN
  • wet aged-related macular degeneration
  • OCT images
  • gray level cooccurrence matrix
  • feature extraction
  • classification
Abstract

EN Progress in medical imaging and computer vision has enabled us to rely on machines for the detection or diagnosis of many diseases, including eye-related problems. One of them is wet age-related macular degeneration (wet AMD) which is a type of age-related macular degeneration. Wet AMD causes the detachment of retinal pigment epithelium layer (RPE) – a condition referred to as pigment epithelium detachment (PED) – and also creates fluid fill region called choroidal neovascularization (CNV). In this paper we present a case study of detecting wet ADM in OCT images. We used a set of 51 images – 21 of sick eyes and 30 of healthy eyes. We employed feature extraction techniques to identify abnormalities in RPE layer (PED and CNV) along with the structural and textural properties of the RPE layer (gray level co-occurrence matrix, GLCM). Specifically, we considered four possible set of features and for each set we constructed k-NN, naive Bayes, support vector machine (SVM) and rule-based classifiers. The best classification performance was obtained for the features capturing the structural and textural properties of the RPE layer and for naive Bayes classifier (accuracy = 96.1%, sensitivity = 91.3%, specificity = 100.0%) and SVM classifier (accuracy = 94.1%, sensitivity = 100.0%, specificity = 93.7%). Our results confirm the usefulness of the features characterizing the RPE layer in the diagnosis of wet AMD.

Pages (from - to)

43 - 51

DOI

10.1007/978-3-319-70063-2_5

URL

https://link.springer.com/chapter/10.1007/978-3-319-70063-2_5

Book

Innovations in Biomedical Engineering

Presented on

Conference on Innovations in Biomedical Engineering, IBE 2017, 19-20.10.2017, Zabrze, Polska

Ministry points / chapter

20

Publication indexed in

WoS (15)