Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Problem „przecieku widma” w procesie oceny jakości energii elektrycznej

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.2] Automation, electronics and electrical engineering

Title variant

EN The problem of “leakage spectrum” in the process of power quality evaluation

Year of publication

2019

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2019 | Journal number: Issue 97

Article type

scientific article

Publication language

polish

Keywords
PL
  • okno pomiarowe
  • przeciek widma
  • wyższe harmoniczne
  • jakość energii elektrycznej
  • FFT
Abstract

PL W artykule przedstawiono wyniki symulacji związane ze zjawiskiem „przecieku widma” w procesie oceny jakości energii elektrycznej. Na wstępie artykuł omawia zagadnienia związane z problematyką potrzeby analizy jakości energii elektrycznej oraz związanego z tą analizą zjawiska „przecieku widma”. Kolejno przedstawione zostały analizowane sygnały wraz z ich opisem funkcyjnym. Dla omówionych przebiegów przeprowadzono analizę widmową FFT z wykorzystaniem programu MATLAB. Podczas symulacji zmieniano częstotliwość sygnału badanego w zakresie dopuszczalnych odchyleń częstotliwości napięcia sieci określonych odpowiednią normą. Przy zmianie wspomnianego parametru monitorowano błędy pomiaru zawartości wyższych harmonicznych przy zastosowaniu wybranych okien czasowych. Artykuł kończy się zebraniem wniosków z przeprowadzonej analizy oraz podsumowaniem.

EN The article presents simulation results related to the phenomenon “spectrum leak” in the process of assessing the quality of electricity. At the beginning, the article discusses issues related to the problem of the need to analyze the quality of electric energy and the phenomenon of "spectrum leakage" associated with this analysis. Subsequently, the analyzed signals were presented along with their functional description. For the discussed runs, FFT spectral analysis was performed using the MATLAB program. During the simulation, the frequency of the tested signal was changed in the range of acceptable voltage deviations of the network defined by the appropriate standard. When changing the frequency, the error of measuring the content of higher harmonics was tested using window function. The article ends with the collection of conclusions from the analysis and the summary.

Pages (from - to)

63 - 73

DOI

10.21008/j.1897-0737.2019.97.0006

URL

http://yadda.icm.edu.pl/baztech/element/bwmeta1.element.baztech-207c01ed-79d9-4c28-aa79-b94753811559

Open Access Mode

publisher's website

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

5

Ministry points / journal in years 2017-2021

5

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.