Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Ekranowanie w układzie rurociągów podziemnych

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.2] Automation, electronics and electrical engineering

Title variant

EN Screening in a system of underground pipelines

Year of publication

2018

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2018 | Journal number: Issue 93

Article type

scientific article

Publication language

polish

Keywords
PL
  • rurociągi przesyłowe
  • linia elektroenergetyczna
  • oddziaływanie indukcyjne
  • ekranowanie
  • symulacja
Abstract

PL Celem niniejszej pracy jest zaprezentowanie metody analizy indukcyjnego oddziaływania linii elektroenergetycznych na układ rurociągów, w którym występuje zjawisko ekranowania. Przedstawiony jest model analityczny dwóch nieskończenie długich rurociągów podziemnych, sprzężonych indukcyjnie oraz konduktancyjnie, znajdujących się w polu magnetycznym pobliskiej linii elektroenergetycznej. Modelowanie takiego układu przeprowadza się również przy zastosowaniu pakietu symulacyjnego PSPICE. Jednorodne odcinki obwodów ziemnopowrotnych (rurociągów) o znanych, pasywnych parametrach jednostkowych symuluje się jako połączenie łańcuchowe czwórników typu π. Elementy aktywne modelu reprezentują zewnętrzne wymuszenie – siłę elektromotoryczną indukowaną wzdłuż rurociągów, a źródła sterowane modelują wzajemne sprzężenia między rurociągami. Przedstawiono ponadto przykładowe symulacje.

EN The paper presents methods of analysis of inductive interference of power line on system of two pipelines with screening effects taken into account. The analytical method enables one to calculate potentials excited along two infinitely long underground pipelines inductively and conductively coupled. The use of the circuit simulation package SPICE (Simulation Program with Integrated Circuit Emphasis) permits also such as analysis. In the approach presented, pipelines are modeled as large multinode electrical equivalent circuits. The circuit is a chain of basic circuits, which are equivalents of homogenous sections of the pipeline with uniform exposure to the interfering electric field associated with the inductive influence. The active elements in the circuit represent the primary electric field whereas the controlled voltage sources model effects of the coupling between pipelines. Usefulness of the analytical method and the SPICE simulation has been illustrated by examples.

Pages (from - to)

143 - 157

DOI

10.21008/j.1897-0737.2018.93.0012

Presented on

Computer Applications in Electrical Engineering 2018, 23-24.04.2018, Poznań, Polska

Full text of article

Download file

Access level to full text

public

Ministry points / journal

9

Ministry points / journal in years 2017-2021

9

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.