Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Wpływ wartości wybranych parametrów modeli elementów systemu elektroenergetycznego na przebiegi w niesymetrycznych stanach pracy

Authors

Title variant

EN The influence of values of selected parameters of power system element models on the waveforms under asymmetrical operating conditions

Year of publication

2018

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2018 | Journal number: Issue 95

Article type

scientific article

Publication language

polish

Keywords
PL
  • system elektroenergetyczny
  • niesymetria obciążenia
  • zwarcie dwufazowe
  • asymetria podprzejściowa generatora
Abstract

PL W artykule przedstawiono model matematyczny systemu elektroenergetycznego (SEE) składającego się z zespołu wytwórczego (z generatorem synchronicznym) połączonego linią energetyczną (przesyłową) wysokiego napięcia z siecią sztywną. Równania stanu i równania wyjścia generatora przedstawiono w układzie współrzędnych d, q, 0 oraz przy użyciu wielkości fazowych stojana generatora, sieci sztywnej i linii energetycznej, szczególnie przydatnych w analizie stanów niesymetrycznych. Opracowano zwarty opis matematyczny całego SEE i obliczono przebiegi odpowiednich wielkości w stanach nieustalonych i ustalonych dla wybranych obciążeń niesymetrycznych. W obliczeniach przedstawionych w artykule uwzględniono zakłócenie stanu ustalonego w postaci zwarcia dwufazowego w linii przesyłowej. Badano oddziaływania układu wzbudzenia i układu regulacji prędkości kątowej generatora oraz wpływ wybranych parametrów modelu generatora na przebiegi.

EN In the paper, there is presented a mathematical model of a power system (PS) consisting of a generating unit (with a synchronous generator) connected by a high voltage power (transmission) line to a bus system. State and output equations of the generator are written in d, q, 0 coordinate system and with use of phase quantities (especially useful in the analysis of asymmetrical states) of the generator stator, bus system and power line. There was developed a compact mathematical description of the whole PS and there were calculated the waveforms of appropriate quantities in steady and transient states for selected asymmetrical loads. The calculations presented in the paper take into account the disturbance of the steady state in the form of a two-phase short-circuit in the transmission line. The influence of the excitation system and the governor of the generator as well as the effect of selected parameters of the generator model on the waveforms were investigated.

Pages (from - to)

117 - 128

DOI

10.21008/j.1897-0737.2018.95.0012

Presented on

Computer Applications in Electrical Engineering 2018, 23-24.04.2018, Poznań, Polska

Full text of article

Download file

Access level to full text

public

Ministry points / journal

9

Ministry points / journal in years 2017-2021

9

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.