Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Determination of hydrodynamic model based on tracer test performed in WWT plant in Kędzierzyn Koźle, Poland

Authors

Year of publication

2016

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2016 | Journal number: Issue 88

Article type

scientific article

Publication language

english

Keywords
EN
  • Bardenpho WWT plant
  • HRT
  • tracer test
  • RTD modeling
Abstract

EN Analysis results of lithium chloride concentrations, which were measured during tracer test performed in wastewater treatment (WWT) plant placed in Kędzierzyn–Koźle, Poland, are presented in the paper. The considered WWT plant operates with a five-stage Bardenpho system for organic content reduction within activated sludge process (ASP). One of the significant factors, which have an impact on the efficiency of the ASP in a biological reactor, is its hydraulic behavior. In this study theoretical and actual retention times were determined by using of mathematical modeling. Three single and multistream dispersion models were applied, i.e. Tanks-in-Series, Extended Tanks-in-Series and a model based on the MARTIN method. Using the last model it was possible to identify multiple wastewater flows in the reactors, which include: main flow and short circuiting flows. Furthermore, it was stated that the theoretical retention times differ from the actual values, obtained through mathematical modeling.

Pages (from - to)

175 - 185

Presented on

Computer Applications in Electrical Engineering 2016, 18-19.04.2016, Poznan, Poland

Full text of article

Download file

Access level to full text

public

Ministry points / journal

9