Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Zaburzenia słabego pola magnetycznego przez zanieczyszczone magnetycznie tworzywa sztuczne

Authors

Title variant

EN Disturbances in low magnetic field caused by magnetically contaminated plastics

Year of publication

2014

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2014 | Journal number: Issue 77

Article type

scientific article

Publication language

polish

Keywords
PL
  • pole magnetyczne
  • magnetometr pompowany optycznie
  • tworzywa sztuczne
  • zaburzenie pola magnetycznego
Abstract

PL Badanie słabych pól magnetycznych wymaga zastosowania precyzyjnych magnetometrów pracujących w układzie różnicowym. Dwa magnetometry pompowane optycznie pracujące w układzie różnicowym pozwalają na pomiary zaburzeń modułu indukcji magnetycznej rzędu 10pT. Dla tak precyzyjnych pomiarów pola magnetycznego niezbędne jest zastosowanie odpowiednich materiałów wchodzących w skład budowy systemu magnetometrycznego. Przedstawiono wyniki analizy zaburzenia pola magnetycznego spowodowane przez amagnetyczne elementy statywu pomiarowego systemu magnetometrycznego, które zostały zanieczyszczone w trakcie produkcji lub obróbki mechanicznej drobinami i opiłkami o właściwościach ferromagnetycznych. Przedstawiono również wyniki badań eksperymentalnych zaburzeń pola magnetycznego wywołanych przez elementy z tworzyw sztucznych.

EN In the study of low magnetic fields precision magnetometers working in a differential system are used. In order to attain a high accuracy of magnetic field measurement, it is necessary to use appropriate materials for the construction of a magnetometric system. Practically during the manufacturing process and mechanical treatment of particular materials, they become contaminated with small particles or filings with ferromagnetic properties. These contaminations cause significant disturbances in the magnetic field in case of taking measurements of very low magnetic fields. An experimental study of the components used for the construction of a rotary support stand for measuring metrological parameters of the magnetometer confirmed that magnetic contaminations have a significant impact on the occurrence of disturbances in the Earth’s magnetic field. Superficial contamination of the materials with steel dust that occurs in machine tools can be efficiently eliminated by magnetic cleaning which consists in pickling of the produced components in a bath of diluted sulphuric acid. Experimental studies confirmed high efficiency of the above method.

Pages (from - to)

29 - 37