Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download BibTeX

Title

To Shade or not to Shade (and how)? Annual heating energy balance and internal temperature in low energy houses in Wrocław, Poland

Authors

[ 1 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Year of publication

2023

Published in

Journal of Physics: Conference Series

Journal year: 2023 | Journal volume: vol. 2654

Article type

scientific article / paper

Publication language

english

Abstract

EN One of the important areas of occupant–building fabric interaction with IEQ consequences is windows' shading. The relevance of shading has been explored through modeling studies in the context of energy, daylighting and thermal comfort, typically aiming to inform the design stage. In owner occupied housing the architectural design sets the scene for subsequent residents' decisions concerning windows treatment. Here, based on varied treatments for 20m2 living room window observed during an in-depth building performance evaluation in same homes, dynamic modeling in TRNSYS is used to establish the related heating loads and internal temperatures. The results allow to rank five shading usage scenarios for three physical settings, namely lack of shading, external blind and internal curtain on lower half of the window, in terms of their overheating mitigation potential, based on simplified assumptions for heating, ventilation and shading practices. The modelling points towards severe overheating issue and crucial impact of shading usage patterns on its mitigation. Yearly modelled share of overheating hours (>26 °C) are almost double for unshaded scenario compared to the most effective shading strategy (25% and 13%). The simulation contributes to understanding of the field monitoring results where the unshaded living rooms experience more severe overheating, and the two shading settings in place are associated with comparable internal thermal conditions, respectively 22% vs. 5% and 6% of yearly share of overheating hours. The simplification of human-HVAC-building interaction model likely obfuscates solar heat gain control contribution to heating load.

Pages (from - to)

012067-1 - 012067-8

DOI

10.1088/1742-6596/2654/1/012067

URL

https://iopscience.iop.org/article/10.1088/1742-6596/2654/1/012067

Comments

Article Number: 012067

Presented on

13th Nordic Symposium on Building Physics NSB 2023, 12-14.06.2023, Aalborg, Denmark

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Ministry points / journal

40