Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Warunki zwarciowe w rozdzielni spowodowane zakłóceniami na różnych elementach sieci elektroenergetycznej

Authors

[ 1 ] Instytut Elektroenergetyki, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Title variant

EN Short-circuit conditions in distribution substation due to disturbances on various elements of the grid

Year of publication

2016

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2016 | Journal number: Issue 86

Article type

scientific article

Publication language

polish

Keywords
PL
  • rozdzielnie najwyższych napięć
  • warunki zwarciowe
  • symulacja
Abstract

PL Prezentowane zagadnienie jest kontynuacją badań w dotyczących oceny czasu trwania zwarcia i dynamicznych skutków zwarciowych w rozdzielniach najwyższych napięć metodą probabilistyczną. Badania są realizowane za pomocą specjalnie opracowywanego modelu do symulacyjnej analizy warunków zwarciowych w rozdzielniach, opartego na metodzie symulacji Monte Carlo. W ramach kolejnego etapu prac oceniono wpływ zakłóceń na różnych elementach sieci na rozkład prawdopodobieństwa prądu zwarciowego i czasu jego przepływu oraz sił dynamicznych w dwóch różnych miejscach rozdzielni 220 kV. Rozpatrzono wpływ zwarć na szynach głównych i w polach rozdzielni, na liniach (długiej i krótkiej) i na transformatorze.

EN The presented question forms a continuation of the research on the probabilisticbased assessment of the short-circuit duration in the EHV distribution stations is reported. In the research work, a model for simulation-based analysis of short-circuit conditions in distribution substations is applied, and the model using the Monte Carlo simulation technique is being especially developed. In the presented successive step of work, the influence of disturbances at different grid elements on the probability distribution of the short-circuit current and its flow duration and the dynamic forces in two different locations in the 220kV distribution station has been assessed. The analysis has been carried out for the faults across the busbar and in the substation’s bays, on the lines (short and long) and in the transformer.

Pages (from - to)

177 - 188

Presented on

Computer Applications in Electrical Engineering 2016, 18-19.04.2016, Poznan, Poland

Full text of article

Download file

Access level to full text

public

Ministry points / journal

9

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.