Corrosion Resistance and Surface Bioactivity of Ti6Al4V Alloy after Finish Turning under Ecological Cutting Conditions
[ 1 ] Instytut Technologii Mechanicznej, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ P ] employee
2021
scientific article
english
- Ti6Al4V alloy
- finish turning
- surface topography
- cooling conditions
- corrosion resistance
- surface bioactivity
- simulated body fluid (SBF)
- minimum quantity lubrication (MQL)
16.11.2021
6917-1 - 6917-16
Article Number: 6917
CC BY (attribution alone)
open journal
final published version
at the time of publication
140
140
3,748