Artykuł

Pobierz BibTeX

Tytuł

Ventilation Strategy for Proper IAQ in Existing Nurseries Buildings - Lesson Learned from the Research during COVID-19 Pandemic

Autorzy

[ 1 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] pracownik

Dyscyplina naukowa (Ustawa 2.0)

[2.10] Inżynieria środowiska, górnictwo i energetyka

Rok publikacji

2022

Opublikowano w

Aerosol and Air Quality Research

Rocznik: 2022 | Tom: vol. 22 | Numer: iss. 3

Typ artykułu

artykuł naukowy

Język publikacji

angielski

Słowa kluczowe
EN
  • ventilation strategy
  • nurseries
  • indoor air quality
  • COVID-19 pandemic
  • decentralized ventilation
Streszczenie

EN During the COVID-19 pandemic, many recommendations were made in the field of limiting the transmission of the SARS-CoV-2 virus, from which we can learn a lesson for determining ventilation strategies in strategic types of buildings (those whose closure during a pandemic is harmful to the economy, e.g., nurseries). The research was aimed at identifying recommendations in the field of ventilation and proposing a solution that would be applicable in existing buildings intended for the care of small children, and which would ensure the proper quality of the building environment, at the same time with low costs incurred by the owners. The outside air pollution (PM 10 ) and the climate in winter (low air temperature) were also taken into account. A strategy was proposed based on the use of decentralized units, dedicated to single rooms, thanks to which the appropriate amount of air is supplied (per person), the air is cleaned and heated in the heat recovery exchanger. It has been shown that the use of heat recovery ensures that the costs of air heating will be significantly lower than during airing. The proposed solutions require two holes in the external wall with a diameter of 160–200 mm (depending on the number of people), which guarantees the technically possible application in existing buildings. The strategy provides suitable conditions for the functioning of nurseries, but can be used in many types of buildings, in cold and temperate climates, where airing of the rooms during winter is not possible, especially in the case of locations where the quality of outdoor air is very poor. The proposed strategy may be applied during a pandemic, but also on a daily basis, because by ensuring the proper quality of indoor air, young children will have healthy and hygienic conditions for development when they are not at home.

Strony (od-do)

210337-1 - 210337-18

DOI

10.4209/aaqr.210337

URL

https://aaqr.org/articles/aaqr-21-11-covid2-0337

Uwagi

Article Number: 210337

Typ licencji

CC BY (uznanie autorstwa)

Tryb otwartego dostępu

otwarte czasopismo

Wersja tekstu w otwartym dostępie

ostateczna wersja opublikowana

Punktacja Ministerstwa / czasopismo

100

Impact Factor

4

Ta strona używa plików Cookies, w celu zapamiętania uwierzytelnionej sesji użytkownika. Aby dowiedzieć się więcej przeczytaj o plikach Cookies i Polityce Prywatności.