Application of the Hybrid MCDM Method for Energy Modernisation of an Existing Public Building - A Case Study

Autorzy

[ 1 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] pracownik

Dyscyplina naukowa (Ustawa 2.0)

[2.10] Inżynieria środowiska, górnictwo i energetyka

Rok publikacji

2023

Opublikowano w

Energies

Rocznik: 2023 | Tom: vol. 16 | Numer: iss. 8

Typ artykułu

artykuł naukowy

Język publikacji

angielski

Słowa kluczowe
EN
  • plus-energy buildings
  • planning methodology
  • multi-criteria analysis
Streszczenie

EN The existing public utility building belonging to the Forest Experimental Station of the Poznań University of Life Sciences, due to high energy consumption and related costs, has qualified for deep energy modernisation or consideration for the construction of a new building. One of the goals is to achieve carbon neutrality and have a positive energy balance. The article uses the hybrid DEMATEL-AHP/ANP-VIKOR method. The methodology used is distinguished by the creation of a set of decision-making criteria and the identification of the relationship between them, which is determined by conducting a survey of a group of experts using the Delphi method, as well as determining the preferences of the decision-maker using a survey of the target group using social research. Two different models of the decision-maker’s preferences have been developed, taking into account the selected decision criteria, and four acceptable technical solutions have been identified. As a result of the calculations performed, a ranking of the solutions has been developed, from the most preferred to the least accepted. Variant 3B has been identified as the best solution with respect to eight evaluation criteria for both of the adopted models of the decision-maker’s preferences. The ranking index Ri coefficient for this variant ranged between 0.733 and 0.901, while for the other variants, it was lower and amounted to between 0.106 and 0.274 for variant 1, 0.166 and 0.290 for variant 2 and 0.403 and 0.437 for variant 3A. The methodology used for the case study has proved to be applicable. The presented methodology can be used to design new buildings (not only residential) with almost zero energy consumption, as well as those with a positive energy balance, and can also be used for deep energy modernisation. In this article, it was applied for the first time to the energy modernisation of an existing public building.

Data udostępnienia online

16.04.2023

Strony (od-do)

3475-1 - 3475-18

DOI

10.3390/en16083475

URL

https://www.mdpi.com/1996-1073/16/8/3475

Uwagi

Article Number: 3475

Typ licencji

CC BY (uznanie autorstwa)

Tryb otwartego dostępu

otwarte czasopismo

Wersja tekstu w otwartym dostępie

ostateczna wersja opublikowana

Czas udostępnienia publikacji w sposób otwarty

w momencie opublikowania

Punktacja Ministerstwa / czasopismo

140

Impact Factor

3,2 [Lista 2022]

Ta strona używa plików Cookies, w celu zapamiętania uwierzytelnionej sesji użytkownika. Aby dowiedzieć się więcej przeczytaj o plikach Cookies i Polityce Prywatności.