Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Dissertation

Download BibTeX

Title

Wpływ parametrów projektowych i operacyjnych systemów wyposażenia technicznego na zużycie energii i komfort klimatyczny w budynku energooszczędnym

Authors

Promoter

[ 1 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Supporting promoter

[ 1 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Reviewers

Title variant

EN The impact of design and operational parameters of technical equipment systems on energy consumption and climatic comfort in an energy-efficient building

Language

polish

Keywords
PL
  • zużycie energii
  • komfort klimatyczny
EN
  • energy consumption
  • climatic comfort
Abstract

PL Przedmiotem pracy były badania parametrów projektowych i operacyjnych systemów wyposażenia technicznego budynku i ich wpływ na zużycie energii i komfort klimatyczny w budynku energooszczędnym, prowadzone na podstawie pomiarów in situ na przestrzeni kilku lat w budynku jednorodzinnym. Przeanalizowano pracę systemu wentylacji mechanicznej z wymiennikiem do odzyskiwania ciepła i gruntowym powietrznym wymiennikiem ciepła. Zaobserwowano ścisłą zależność pomiędzy profilem użytkowania pomieszczeń, a warunkami klimatycznymi i zużyciem energii. Wykazano, że w przypadku jednorurowego gruntowego wymiennika ciepła o dużym spadku podłużnym (w badanym obiekcie 4 %), gdy przepływ powietrza odbywa się w kierunku przeciwnym do spadku dna wymiennika, temperatura gruntu otaczającego wymiennik na jego długości zmienia się (zimą zmniejsza, latem zwiększa), co po przekroczeniu punktu przełamania prowadzi do rozpoczęcia procesu odwrotnego od początkowo przebiegającego.

EN The subject of the study was the investigation of the design and operational parameters of technical equipment systems in a building and their impact on energy consumption and indoor comfort in an energy-efficient building, based on in-situ measurements over several years in a single-family house. The operation of the mechanical ventilation system with a heat recovery exchanger and a ground air heat exchanger was analyzed. A close relationship was observed between the occupancy profiles of the rooms, climatic conditions, and energy consumption. It was demonstrated that in the case of a single-pipe ground heat exchanger with a significant longitudinal drop (4% in the studied facility), when the airflow occurs in the opposite direction to the slope of the exchanger, the temperature of the surrounding ground along its length changes (decreases in winter, increases in summer), which, after reaching a turning point, initiates a reversed process from the initially established one.

Number of pages

179

Scientific discipline (Law 2.0)

environmental engineering, mining and energy

Signature of printed version

DrOIN 2317

On-line catalog

to2024500754

Full text of dissertation

Download file

Access level to full text

public

First review

Hanna Jędrzejuk

Place

Warszawa, Polska

Date

07.09.2023

Language

polish

Review text

Download file

Access level to review text

public

Second review

Jan Wajs

Place

Gdańsk, Polska

Date

27.09.2023

Language

polish

Review text

Download file

Access level to review text

public

Dissertation status

dissertation

Place of defense

Poznań, Polska

Date of defense

14.11.2023

Unit granting title

Rada Dyscypliny Inżynieria Środowiska, Górnictwo i Energetyka Politechniki Poznańskiej

Obtained title

doktor nauk inżynieryjno-technicznych w dyscyplinie: inżynieria środowiska, górnictwo i energetyka

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.