Wpływ ekstremalnych zjawisk atmosferycznych na system elektroenergetyczny

Authors

[ 1 ] Instytut Elektroenergetyki, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Title variant

EN The influence of extreme weather conditions on the power system

Year of publication

2018

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2018 | Journal number: Issue 94

Article type

scientific article

Publication language

polish

Keywords
PL
  • bezpieczeństwo energetyczne
  • awarie systemu elektroenergetycznego
  • ekstremalne zjawiska atmosferyczne
  • zwis przewodów
Abstract

PL Podstawowym zadaniem systemu elektroenergetycznego jest zapewnienie ciągłości i niezawodności dostaw energii elektrycznej. W warunkach realnego niebezpieczeństwa wystąpienia awarii systemowych, do których przyczyn należy zaliczyć czynniki atmosferyczne, techniczne oraz czynniki ludzkie, istnieje ryzyko związane z zagrożeniem bezpieczeństwa systemu elektroenergetycznego. Do najczęstszych przyczyn awarii systemowych należą ekstremalne warunki atmosferyczne, których wpływ na pracę systemu elektroenergetycznego zostanie przeanalizowany w niniejszej pracy. Dla trzech wariantów ekstremalnych warunków atmosferycznych, takich jak osad sadzi, silny wiatr i wysoka temperatura, przedstawiona zostanie zmiana wysokości zwisu na przykładzie przęsła linii 20 kV.

EN The major task of the power system is to ensure the continuity and reliability of electricity supply. In conditions of real danger of systemic failures, which reasons include atmospheric, technical and human factors, there is a risk related to the threat to the security of the power system. The most common causes of systemic failures include extreme atmospheric conditions, the impact of which on the operation of the power system will be analyzed in this work. For three variants of extreme weather conditions, such as planting sludge, strong wind and high temperature, there will be shown the changes in the overhead line slack on the example of a 20 kV span.

Pages (from - to)

87 - 98

DOI

10.21008/j.1897-0737.2018.94.0008

URL

http://www.iee.put.poznan.pl/wydawnictwa/archiwum/ArtSzczegoly.aspx?ArtId=4029

Presented on

Computer Applications in Electrical Engineering 2018, 23-24.04.2018, Poznań, Polska