Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Szacowanie wartości temperatury złącza półprzewodnikowego na podstawie wartości temperatury wyprowadzenia diody

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.2] Automation, electronics and electrical engineering

Title variant

EN Estimate of semiconductor diode junction temperature based on diode PIN

Year of publication

2018

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2018 | Journal number: Issue 95

Article type

scientific article

Publication language

polish

Keywords
PL
  • dioda półprzewodnikowa
  • wartość temperatury złącza
  • wyprowadzenie
  • termowizja
Abstract

PL W niniejszym artykule przedstawiono związek pomiędzy wartością temperatury wyprowadzenia i wartością temperatury złącza diody półprzewodnikowej w obudowie do montażu powierzchniowego. Przedstawiono parametry wybranych diod półprzewodnikowych. Omówiono metodykę przeprowadzonych badań i skonstruowany układ pomiarowy. Zaprezentowano sposób szacowania temperatury złącza diody półprzewodnikowej na podstawie charakterystyki wiążącej wartość spadku napięcia UF i wartość temperatury. Przedstawiono dobór wartości współczynnika emisyjności wyprowadzenia ε pozwalający uzyskać wystarczająco dokładną wartość temperatury wyprowadzenia, na podstawie której możliwe jest oszacowanie wartości temperatury złącza. Dodatkowo przedstawiono zastosowaną kamerę termowizyjną.

EN Junction temperature is one of the most important parameters of semiconductor diode. Diode operation depends on junction temperature. Correct measurement is difficult because of a small size of the object. The measurements are especially complex for SMD (Surface Mount Device) diodes, which have a size of a few millimeters. Contact measurement method with temperature sensor is unreliable. Alternative way is the noncontact thermovision measurement, which can give an information about the temperature of the diode pins. In practice the information about diode junction is more significant. This article describe relation between a result of diode pins thermovision measurement and temperature of junction. The diodes with two semiconductors junctions in the same case was used. Junctions of the diodes was connected in various kind (common anode and common cathode). It was found relation, which allow estimate of junction temperature value based on pin temperature.

Pages (from - to)

243 - 254

DOI

10.21008/j.1897-0737.2018.95.0023

Presented on

Computer Applications in Electrical Engineering 2018, 23-24.04.2018, Poznań, Polska

License type

other

Open Access Mode

publisher's website

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

9

Ministry points / journal in years 2017-2021

9

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.