Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Termowizyjne obserwacje małych elementów

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.2] Automation, electronics and electrical engineering

Title variant

EN Thermovision measurements of small parts

Year of publication

2019

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2019 | Journal number: Issue 100

Article type

scientific article

Publication language

polish

Keywords
PL
  • termowizja
  • metrologia
  • elektronika
Abstract

PL W artykule opisano wpływ odległości pomiędzy obiektywem kamer termowizyjnych, a obserwowaną powierzchnią na ostrość uzyskanego obrazu. Pokazano zależność wielkości pola widzenia matrycy detektorów od odległości pomiędzy obiektywem i obserwowaną powierzchnią oraz zależność wielkości pola widzenia pojedynczego detektora od odległości pomiędzy obiektywem i obserwowaną powierzchnią. Wyjaśniono wpływ rozdzielczości matrycy na wielkość pola widzenia pojedynczego detektora. Zaproponowano, w jaki sposób dobrać obiektyw, by uzyskany termogram był ostry oraz możliwe było osiągnięcie takiej rozdzielczości geometrycznej, która pozwoli wystarczająco dokładnie odwzorować rozkład temperatur na obserwowanej powierzchni.

EN The article describes the influence of the distance between the lens and the observed surface on the sharpness of the obtained image. The relation between the size of the field of view of the detector array and the distance between the lens and the observed surface as well as the dependence of the field of view of a single detector on the distance between the lens and the observed surface is shown. The effect of matrix resolution on the field of view of a single detector was explained. It was proposed how to choose the lens, so that the obtained thermogram was sharp and it was possible to achieve such a geometric resolution that allows to accurately reproduce the temperature distribution on the observed surface.

Pages (from - to)

39 - 49

DOI

10.21008/j.1897-0737.2019.100.0004

Presented on

Computer Applications in Electrical Engineering 2019, 15.04.2019, Poznań, Polska

Open Access Mode

publisher's website

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

5

Ministry points / journal in years 2017-2021

5