Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Stereoskopowy pomiar odległości

Authors

Title variant

EN Stereoscopic Distance Measurement

Year of publication

2017

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2017 | Journal number: Issue 89

Article type

scientific article

Publication language

polish

Keywords
PL
  • pomiar odległości
  • wykrywanie obiektu
  • dalmierze
  • obraz stereoskopowy
Abstract

PL Pomiar odległości jest jedną z podstawowych operacji spotykanych w systemach przemysłowych i militarnych. W pracy przedstawiono urządzenie do precyzyjnego pomiaru małych odległości nieprzekraczających 15 m. Urządzenie będzie zainstalowane na platformie mobilnej przewidzianej do pomiaru temperatury linii wysokiego napięcia z użyciem kamery termowizyjnej. Pomiar tą metodą wymaga określenia odległości od obiektu. Wartość odległości jest konieczna do prawidłowej interpretacji obrazu z kamery. Zaproponowano stereoskopowy pomiar odległości z użyciem dwóch kamer. Metoda taka umożliwia pomiar odległości od dowolnego punktu widocznego w dwóch kamerach. Kąt widzenia urządzenia jest zbliżony do kąta widzenia kamer, a więc nie ma potrzeby precyzyjnego nakierowywania urządzenia na obiekt. Najważniejszym zagadnieniem jest wyznaczenie współrzędnych obiektu w obrazie z kamer. Jest to generalnie zadanie o dużej złożoności obliczeniowej. W przeprowadzonym eksperymencie obiekt jest wykrywany na podstawie barwy i jasności.

EN The distance measurement is one of the basic operations encountered in industrial systems or military. In this work a device for the precise measurement of small distances not exceeding 15 m is presented. The device will be installed on a mobile platform that will be applied for temperature measurement of high voltage lines with the use of the infrared camera. The temperature measurement by this method requires the determination of the distance to the object. The distance is needed for the proper interpretation of the camera output. The stereoscopic distance measurement using two cameras is proposed. The method allows for the measurement of distance from any point visible in both cameras. The viewing angle of the device is close to the viewing angles of cameras so there is no need for centering the device onto the object. The most important problem is the determination of object coordinates in the picture captured from the camera. It is, in general, the task of high computational complexity. In the performed experiment the object position is being determined using its colour and intensity. The measurement algorithm is described along with the selected results.

Pages (from - to)

281 - 291

DOI

10.21008/j.1897-0737.2017.89.0026

Presented on

Computer Applications in Electrical Engineering 2017, 10-11.04.2017, Poznań, Polska

Full text of article

Download file

Access level to full text

public

Ministry points / journal

9

Ministry points / journal in years 2017-2021

9

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.