Abstract

PL W artykule przedstawiono wibroakustyczną metodę diagnozowania stanu mechanicznego części aktywnej transformatora. Proponowana metoda opiera się na analizie zmian w dziedzinie czasu znormalizowanej wartości przyspieszenia drgań zarejestrowanych na powierzchni kadzi. Analizie podlega przy tym stan nieustalonej pracy nieobciążonego transformatora w czasie kilku pierwszych sekund od załączenia zasilania. Metodę oparto na algorytmie obliczania modułu sygnału analitycznego dla rzeczywistego sygnału reprezentującego zarejestrowane przyspieszenie drgań. Prezentowaną metodę przetestowano w warunkach laboratoryjnych i przemysłowych. Badania wykazały szczególną przydatność prezentowanej metody w połączeniu z metodą FRA (Frequency Response Analysis) do diagnozowania defektów uzwojeń.

EN This article presents a vibroacoustic method of diagnosing mechanical condition of the active part of the transformer. The proposed method is based on the analysis of changes in the time-domain normalized values of vibration acceleration which are recorded on the surface of the tank. The subject of this analysis is the unknown mechanical status of unloaded transformer during the first few seconds after power-up (transient state). The method is based on an algorithm for calculating the analytical signal module for the real-value signal, representing recorded vibration acceleration. Presented method has been tested in laboratory and industrial applications. Studies have shown particular suitability of the method, in conjunction with the FRA (Frequency Response Analysis) method, for diagnosing failures of transformer windings.

Pages (from - to)

119 - 126