Adaptive Zero-Sequence Overcurrent Criterion for Earth Fault Detection for Fault Current Passage Indicators in Resistor Grounded Medium Voltage Networks

Authors

[ 1 ] Instytut Elektroenergetyki, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Year of publication

2021

Published in

IEEE Access

Journal year: 2021 | Journal volume: vol. 9

Article type

scientific article

Publication language

english

Keywords
EN
  • adaptive criterion
  • earth fault
  • earth fault passage indicator
  • medium voltage network
  • resistor grounded neutral point
  • zero-sequence current
Abstract

PL Earth faults are the most common disturbances in medium voltage networks. They cause threats to equipment and people, and reduce the quality and reliability of electricity supply. Detection and localization of earth faults is a key challenge to network operators, therefore it is important to constantly develop criteria that allow for an unequivocal assessment of the current network state. This article focuses analysis of effectiveness of classic zero-sequence overcurrent criterion and on modification of the zero-sequence overcurrent criterion applied in fault current passage indicators, which are the devices used to effectively detect and locate earth faults. Two new adaptation criteria for networks with resistor grounded neutral point have been proposed, which enable significant improvement of the effectiveness of earth faults detection, in particular high impedance ones. The effectiveness of the criteria was verified computationally and in simulations. In certain situations, the proposed solutions may be over 40% more effective than the classic criterion. The value of detected transition resistance R F also increases significantly. All the above-mentioned advantages make their potential use in practice very beneficial.

Date of online publication

27.04.2021

Pages (from - to)

63952 - 63965

DOI

10.1109/ACCESS.2021.3076022

URL

https://ieeexplore.ieee.org/document/9416642

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

100

Ministry points / journal in years 2017-2021

100

Impact Factor

3,476

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.