Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download BibTeX

Title

Multi-criteria diagnostics of historic buildings with the use of 3D laser scanning (a case study)

Authors

[ 1 ] Instytut Budownictwa, Wydział Inżynierii Lądowej i Transportu, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.7] Civil engineering, geodesy and transport

Year of publication

2022

Published in

Bulletin of the Polish Academy of Sciences. Technical Sciences

Journal year: 2022 | Journal volume: vol. 70 | Journal number: no. 2

Article type

scientific article

Publication language

english

Keywords
EN
  • laser scanning
  • diagnostics
  • historic buildings
  • limit state method
  • beam deflection
  • mycological tests
Abstract

EN The protection and use of historic buildings is a difficult and costly task. Most often, these objects are under conservatory protection and any interference in their structure requires appropriate consent. On the other hand, carrying out construction works on historic buildings carries a high risk of their damage or even destruction. Therefore, proper prior diagnostics is an extremely important factor affecting the scope and manner of works to be conducted. The paper presents the use of 3D scanning to determine the deflection of the ceiling under the Column Hall of the historic Palace, the floor of which showed elasticity, recorded during changing service loads. After identifying the places with the greatest deflections, based on data from 3D laser scanning, test holes were made and wood samples from the ceiling were taken to perform moisture content and mycological tests. An endoscopic inspection camera was inserted into test holes, providing the basis for recognizing the structure of the ceiling i.e., arrangement of layers as well as dimensions and spacing of ceiling beams. Strength calculations were made with the limit state method resulted in determination of the maximum permissible service load on the ceiling. The presented course of action in diagnostics of the analysed historic building may be an example of a preliminary procedure to be taken before deciding on changes in the manner of use of historic buildings or the functionalities of their individual parts.

Pages (from - to)

e140373-1 - e140373-10

DOI

10.24425/bpasts.2022.140373

URL

https://journals.pan.pl/Content/122224/PDF/_00_02499_Bpast.No.70(1)_18.01.22_EA_.pdf

Comments

Article Number: e140373

License type

CC BY-NC-ND (attribution - noncommercial - no derivatives)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

in press

Ministry points / journal

100

Impact Factor

1,2