Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download BibTeX

Title

Accuracy of the New Method of Alignment of Workpiece Using Structural-Light 3D Scanner

Authors

[ 1 ] Instytut Technologii Mechanicznej, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.9] Mechanical engineering

Year of publication

2022

Published in

Advances in Science and Technology Research Journal

Journal year: 2022 | Journal volume: vol. 16 | Journal number: iss. 1

Article type

scientific article

Publication language

english

Keywords
EN
  • workpiece aligning
  • casting evaluation
  • optical measurement
  • marking out
Abstract

EN This paper presents a new method of aligning workpieces for machining by means of optical measurements followed by the results of verification tests of this method. The overview of modern assessment methods of irregularly shaped blanks are discussed in this study, with particular emphasis on cast iron castings, as well as on problems related to their positioning and fixing for machining. A flowchart of the proposed method and its verification results in industrial conditions are also presented. The essence of the method is based on the comparison of two spatial models: a designed workpiece model and the actual model of a casting produced with a coordinate measuring technique. A series of six iron castings were tested. The obtained results indicate that the errors caused by locating amounted to a maximum of 2 mm (average 0.5 mm) and were three times lower than actual machining allowances. This points to the correctness of the developed method and the great potential for its industrial application. Additionally, a method for improving locating accuracy by modifying the shape of the retaining pin is presented.

Date of online publication

02.01.2022

Pages (from - to)

1 - 14

DOI

10.12913/22998624/144541

URL

http://www.astrj.com/Accuracy-of-the-New-Method-of-Alignment-of-Workpiece-Using-Structural-Light-3D-Scanner,144541,0,2.html

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Ministry points / journal

100

Impact Factor

1,1