Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Dynamic Stability Evaluation of an Integrated Biodiesel-Geothermal Power Plant-Based Power System with Spotted Hyena Optimized Cascade Controller

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Automatyki, Robotyki i Elektrotechniki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.2] Automation, electronics, electrical engineering and space technology

Year of publication

2022

Published in

Sustainability

Journal year: 2022 | Journal volume: vol. 14 | Journal number: iss. 22

Article type

scientific article

Publication language

english

Keywords
EN
  • automatic generation control
  • geothermal power plant
  • redox flow battery
  • biodiesel plant
  • spotted hyena optimizer
  • particle swarm optimization
  • controller
  • time delay
Abstract

EN The perception of automatic generation control (AGC) has a massive part in delivering eminence power in an interrelated structure. To acquire eminence power by monitoring the fluctuations of frequency and tie-link power, an appropriate controller strategy is essential. This work explores AGC learning under the traditional situation. In this study, we employ a cascade controller with proportional amalgamation with a tilt-integral-derivative with a filter (TIDN) and fractional order integral-derivative (FOID), named TIDN-FOID. In order to acquire the controller’s attributes, a meta-heuristic optimization algorithm spotted hyena optimizer (SHO) is employed. Several investigations express the excellency of the TIDN-FOID controller over other controllers from outlook regarding the lessened level of peak_overshoot, peak_undershoot, and settling_time for the considered structure. The structure comprises thermal, biodiesel units in area 1, thermal, and geothermal units in area-2, and hydrothermal units in area-3. Both biodiesel and GPP have a better effect on system dynamics even in the presence of time delay. Action in the redox flow battery is also examined, providing a noteworthy outcome. Eigenvalue assessment is carried out to comment on the stability of the system. TIDN-FOID parameter values at nominal conditions are appropriate for a higher disturbance value without the need for optimization.

Date of online publication

10.11.2022

Pages (from - to)

14842-1 - 14842-26

DOI

10.3390/su142214842

URL

https://www.mdpi.com/2071-1050/14/22/14842/htm

Comments

Article number: 14842

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Release date

10.11.2022

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

100

Impact Factor

3,9

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.