Improving the Efficiency of Earth Fault Detection by Fault Current Passage Indicators in Medium-Voltage Compensated Overhead Networks

Authors

[ 1 ] Instytut Elektroenergetyki, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Year of publication

2022

Published in

Energies

Journal year: 2022 | Journal volume: vol. 15 | Journal number: iss. 23

Article type

scientific article

Publication language

english

Keywords
EN
  • earth fault detection
  • fault current passage indicator
  • compensated MV network
  • efficiency improving
  • high-resistance fault
PL
  • zwarcia doziemne
  • sygnalizator przepływu prądu zwarciowego
  • skompensowana sieć SN
  • poprawa skuteczności
  • zwarcie wysokooporowe
Abstract

EN The article presents a method for detecting earth faults in a compensated medium-voltage network, which can be used especially in fault current passage indicators, but also in standard protection devices. The method is based on the adaptation process of the zero-sequence current protection setting, with the adaptation factor depending on the current value of the zero-sequence voltage. In this article, a comparative analysis of the classical and adaptive zero-sequence current criterion is conducted, taking into account the errors of the measuring system. The results of simulations performed in the PSCad environment are also presented. For a representative set of example short circuits, it was shown that the effectiveness of the presented criterion can be more than 50% higher than that of the standard criteria, taking into account the range of detected transition resistances. A comparison of the proposed method with admittance criteria was also drawn, and it was shown that it is suitable for the detection of high-resistance earth faults.

Pages (from - to)

9007-1 - 9007-19

DOI

10.3390/en15239007

URL

https://www.mdpi.com/1996-1073/15/23/9007

Comments

article number: 9007

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final author's version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

140

Impact Factor

3,2

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.