Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Determination of Cd, Pb and Zn in Polymers by Laser Ablation Microwave Induced Plasma Optical Emission Spectrometry

Authors

[ 1 ] Instytut Chemii i Elektrochemii Technicznej, Wydział Technologii Chemicznej, Politechnika Poznańska | [ 2 ] Wydział Technologii Chemicznej, Politechnika Poznańska | [ P ] employee | [ SzD ] doctoral school student | [ E ] pensioner

Scientific discipline (Law 2.0)

[7.6] Chemical sciences

Year of publication

2023

Published in

Ecological Chemistry and Engineering S

Journal year: 2023 | Journal volume: vol. 30 | Journal number: iss. 3

Article type

scientific article

Publication language

english

Keywords
EN
  • laser ablation (LA)
  • microwave induced plasma optical emission spectrometry (MIP OES)
  • plastic materials
  • simultaneous determination
  • trace elements
Abstract

EN The potential of laser ablation microwave induced plasma optical emission spectrometry (LA-MIP OES) for the analysis of plastic materials has been investigated. Inorganic species, e.g., metals may be added to them as additives, anti-oxidising agents, stabilisers, plasticisers, colorants and catalytic residues, contaminants and may be present in a wide range of concentrations. The study revealed elevated content of trace elements (Cd, Pb and Zn) which are components of poly(vinyl chloride) (PVC) and polyethylene (PE). Laser ablation using wavelengths of 266 nm as a sampling method for MIP OES was used. The result achieved using elaborated system were compared with those obtained after polymer samples decomposition in high pressure-temperature focused microwave heating digestion system and standard sample pneumatic nebulisation (PN) to MIP OES spectrometer. The calibration strategy using cellulose pellets as support for qualitative analysis for element determination in polymers by LA-MIP OES was proposed. This analytical performance of the LA-MIP OES system was characterised by a determination of the limits of detection (LODs) and precision (RSDs) for elements tested. The experimental concentration detection limits for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3σblank criterion, peak height) were 2 μg g-1, 3 μg g-1 and 5 μg g-1 for Cd, Pb and Zn, respectively. The method offers relatively good precision (RSD ranged from 3 % to 5 %) for micro sampling analysis.

Date of online publication

15.07.2023

Pages (from - to)

405 - 416

DOI

10.2478/eces-2023-0035

URL

https://sciendo.com/article/10.2478/eces-2023-0035

License type

CC BY-NC-ND (attribution - noncommercial - no derivatives)

Open Access Mode

open journal

Open Access Text Version

final published version

Release date

15.07.2023

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

200

Impact Factor

1,9 [List 2022]

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.