Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download BibTeX

Title

Effect of screw angulation and multiple insertions on load-to-failure of polyaxial locking system

Authors

[ 1 ] Instytut Technologii Mechanicznej, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ 2 ] Instytut Mechaniki Stosowanej, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.9] Mechanical engineering

Year of publication

2023

Published in

PLoS ONE

Journal year: 2023 | Journal volume: vol. 18 | Journal number: iss. 12

Article type

scientific article

Publication language

english

Abstract

EN Purpose: Polyaxial locking plates rely on the alignment between the thread-to-thread connections of the screw head and the plate hole. These implants have provided substantial support for surgeons. In particular, extended screw positioning have proven to be beneficial in the fixation of challenging fractures. This study aimed to investigate the mechanical properties of ChM 5.0 ChLP polyaxial screws inserted in off-axis trajectories, including multiple insertions and to correlate these parameters with the screw head and the plate hole thread-to-thread engagement. Methods: Polyaxial locking screws were inserted into the plates at various angles (0°,10°,15°, -15° off-axis). Multiple time inserted screws were placed firstly at 15°, then 0° and finally -15° off-axis in the same plate hole. A microCT scan of the plate-hole and screw-head interface was conducted before destructive tests. Representative screws from each group were also examined by Scanning Electron Microscope. Results: The standard insertion at 0° sustained the greatest maximum bending strength without relocation in the screw hole. Screws inserted at 10° and 15° (one time) showed a significant reduction in load-to-failure of up to 36% and 55%, (p = 0.001) (p = 0.001) respectively. Screws inserted at -15° after a maximum of three multiple insertions with angle shift, showed a total reduction in force of up to 70% (p = 0.001). A microCT analysis of thread engagement showed significant correlations. However, the results obtained for multiple insertions were highly variable. Conclusions: ChM 5.0 ChLP polyaxial locking system has valuable properties that foster fracture fixation, providing various surgical options. Nevertheless, the freedom of off-axis placement and multiple insertions of the screws comes at the price of reduced force. When possible surgeons should minimize the angles of insertions.

Date of online publication

11.12.2023

Pages (from - to)

e0295526-1 - e0295526-15

DOI

10.1371/journal.pone.0295526

URL

https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0295526

Comments

Article Number: e0295526

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Ministry points / journal

140

Impact Factor

2,9

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.