Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

An optimized integral performance criterion based commercial PID controller design for boost converter

Authors

[ 1 ] Instytut Elektrotechniki i Elektroniki Przemysłowej, Wydział Automatyki, Robotyki i Elektrotechniki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.2] Automation, electronics, electrical engineering and space technologies

Year of publication

2024

Published in

Journal of Electrical Engineering

Journal year: 2024 | Journal volume: vol. 75 | Journal number: no. 4

Article type

scientific article

Publication language

english

Keywords
EN
  • DC-DC boost converter
  • optimal PID controller parameters
  • fractional order PID
  • ISA-PID
  • PSO
Abstract

EN Boost converters often face challenges such as sluggish dynamic behavior, inadequate voltage regulation, and variations in input voltage and load current. These issues necessitate the need for closed-loop operation. Nature-inspired optimization algorithms (NIOA) have demonstrated their effectiveness in delivering enhanced solutions for various engineering problems. Several studies have been conducted on the use of proportional-integral-derivative (PID) controllers for controlling boost converters, as documented in the literature. Some studies have shown that using fractional order PID (FO-PID) controllers can lead to better performance than traditional PID controllers. Nevertheless, implementing FO-PID can be quite complex. Considering the widespread use of commercial PID controllers in industrial settings, this study focuses on finding the best tuning for these controllers in DC-DC boost converters. The approach used is particle swarm optimization (PSO) based on integral performance criteria. Simulation results indicate that the proposed controller achieves superior performance, evidenced by the lowest settling time, overshoot, integral absolute error (IAE), and integral squared error (ISE) values under varying input voltage and load current conditions, compared to both PID and FO-PID controllers. These findings have been confirmed through hardware implementation, which demonstrates the effectiveness of the proposed controller.

Pages (from - to)

258 - 267

DOI

10.2478/jee-2024-0032

URL

https://sciendo.com/article/10.2478/jee-2024-0032

License type

CC BY-NC-ND (attribution - noncommercial - no derivatives)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

40

Impact Factor

1 [List 2023]

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.