Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Doziemne zwarcia przerywane w sieci średniego napięcia

Authors

[ 1 ] Instytut Elektroenergetyki, Wydział Elektryczny, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Title variant

EN Intermittent earth faults in MV grid

Year of publication

2017

Published in

Poznan University of Technology Academic Journals. Electrical Engineering

Journal year: 2017 | Journal number: Issue 90

Article type

scientific article

Publication language

polish

Keywords
PL
  • EMTP/ATP
  • zwarcie doziemne
  • zwarcia przerywane
  • sieć SN
Abstract

PL Artykuł porusza problemy związane ze zwarciami doziemnymi w sieci SN o charakterze przerywanym. Analizowane są sytuacje, w których punkt neutralny sieci uziemiony jest przez rezystor lub przez dławik gaszący z układem AWSCz. Badania dotyczą przede wszystkim przebiegów prądów i napięć w wybranych liniach sieci, wartości i przebiegu w czasie składowych symetrycznych tych wielkości oraz parametrów charakterystycznych dla zwarć doziemnych. Wyznaczana jest także średnia wartość wybranych wielkości do oceny możliwości detekcji zwarć przez współcześnie eksploatowane zabezpieczenia. Oceniona została możliwość zastosowania kryteriów admitancyjnych w detekcji zwarć przerywanych, zwłaszcza w odniesieniu do sygnalizatorów przepływu prądu zwarcia doziemnego.

EN The article focuses on problems related to earth faults in the MV network of an intermittent character. There are situations in which the neutral point of the network is grounded through a resistor or coil with Active Current Forcing Automation (AWSCz) analysed. The study relate primarily to current and voltage waveforms on selected lines in network, values and time course of symmetrical components of these values and parameters characteristic of the earth fault. In the simulation the average value of the selected signals is calculated. This is to assessing the possibility to detect earth faults by modem IED. It was evaluated for the possibility of applying the admittance criteria to detect intermittent earth faults in particular with regard to the earth fault passage indicators.

Pages (from - to)

101 - 112

DOI

10.21008/j.1897-0737.2017.90.0009

URL

http://tiny.pl/g48wg

Presented on

Computer Applications in Electrical Engineering 2017, 10-11.04.2017, Poznań, Polska

Open Access Mode

publisher's website

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

9

Ministry points / journal in years 2017-2021

9

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.