Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download BibTeX

Title

Effect of surface corrugation on cooling capacity of ceiling panel

Authors

[ 1 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Year of publication

2020

Published in

Thermal Science and Engineering Progress

Journal year: 2020 | Journal volume: vol. 19

Article type

scientific article

Publication language

english

Keywords
EN
  • cooling enhancement
  • corrugated surface
  • ceiling panel
  • theoretical study
  • experimental validation
Abstract

EN In this paper surface corrugation as a method of capacity enhancement of ceiling panels is presented. The triangular corrugation shape was analyzed. Influence of corrugation length L and corrugation angle β on panel cooling capacity was investigated theoretically. The calculation model was validated experimentally. In calculations the range of corrugation length L was from 30 mm to 120 mm, and the range of corrugation angle β was from 30° to 180°. In experiments the values of the above parameters were: L = 0.04 m, β = 90°, and β = 180°. A special cuvette-type-laboratory panel was used to obtain nearly uniform temperature distribution at the entire cooling surface. The width and length of the laboratory panel were 380 mm and 1502 mm, respectively. The panel surface emissivity was ɛ = 0.9. Calculations have shown that in the typical room conditions the cooling power of the panel with small values L = 30 mm and β = 30° can achieve even 121 W/m2 and it can be up to 90% higher than the specific power of a reference panel with a flat surface. For geometry more desirable from an operating point of view: L = 40 mm and β = 90°, both experimental and theoretical results have shown that the cooling power of the corrugated surface increased by 15÷20% compared to a traditional flat surface. A physical interpretation of the regularities found is presented.

Date of online publication

01.10.2020

Pages (from - to)

100572-1 - 100572-8

DOI

10.1016/j.tsep.2020.100572

URL

https://www.sciencedirect.com/science/article/pii/S2451904920300901

Comments

article number: 100572

Ministry points / journal

20

Ministry points / journal in years 2017-2021

20

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.