Examination of the Impact of Vertebral Displacement on the Surface Area of Intervertebral Foramina

Authors

[ 1 ] Instytut Robotyki i Inteligencji Maszynowej, Wydział Automatyki, Robotyki i Elektrotechniki, Politechnika Poznańska | [ 2 ] Instytut Mechaniki Stosowanej, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ P ] employee | [ D ] phd student

Scientific discipline (Law 2.0)

[2.2] Automation, electronics and electrical engineering

Year of publication

2021

Chapter type

chapter in monograph

Publication language

english

Keywords
EN
  • spine
  • intervertebral foramina
  • surface area estimation
Abstract

EN In the course of degenerative spine disease, as a result of damage to the intervertebral discs and the formation of spondylophytes, i.e. the bone spurs, there is a possibility of narrowing of the intervertebral foramina—the openings for passage of the nerve structures of the spinal cord. Foramina lumen reduction causes compression of the spinal nerves, which can result in paralysis symptoms. It may be the cause of pain, which is currently one of the most common reasons for medical consultations. The aim is to experimentally verify the method of determining the changes in the surface area of the intervertebral foramina as a result of vertebral displacement. The material for the study consisted of computer models of two vertebrae, L2 and L3. The anatomical points forming intervertebral foramina were marked and connected them with a parametric curve—spline. The following step consisted of the simulation movement of one vertebra in relation to the other in the directions x, y, z. In order to examine the changes in the surface area of the intervertebral foramen as a result of vertebral movements, we conducted a simulation study consisting of the reduction of the distance between vertebrae. The range of motion was set to 4 mm, with a step of 0.2 mm. The goal of the research was achieved, aiming to verify the method of determining and monitoring changes in the surface area of intervertebral foramina. Thanks to the verification of the described method, it will be possible to develop it further, aiming to use it in treatment process of the degenerative lumbosacral spine disease.

Pages (from - to)

55 - 62

DOI

10.1007/978-3-030-52180-6_7

URL

https://link.springer.com/chapter/10.1007/978-3-030-52180-6_7

Book

Innovations in Biomedical Engineering

Presented on

International Scientific Conference Advances in Applied Biomechanics, AAB 2020, 15-17.05.2020, Wisła, Poland

Ministry points / chapter

20

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.