Thermal imaging of the disc brake and drive train in an electric locomotive in field conditions

Authors

[ 1 ] Instytut Transportu, Wydział Inżynierii Lądowej i Transportu, Politechnika Poznańska | [ 2 ] Wydział Inżynierii Lądowej i Transportu, Politechnika Poznańska | [ P ] employee | [ SzD ] doctoral school student

Scientific discipline (Law 2.0)

[2.7] Civil engineering, geodesy and transport

Title variant

PL Termowizja hamulca tarczowego i układu napędowego w lokomotywie elektrycznej w warunkach polowych

Year of publication

2024

Published in

Combustion Engines

Journal year: 2024 | Journal number: no. 1 (196)

Article type

scientific article

Publication language

english

Keywords
EN
  • thermal imaging
  • emissivity
  • disc brake
  • electric locomotive
  • drive train system
PL
  • kamera termowizyjna
  • emisyjność
  • hamulec tarczowy
  • lokomotywa elektryczna
  • układ napędowy
Abstract

EN The article presents the results of thermovision tests of the disc brake and the drive system components located in its vicinity on the 111Ed electric locomotive in field conditions. For this locomotive, tests were carried out on a test track to measure the temperature of the disc and the temperature of other devices that were installed close to the brake disc. These tests were performed pointwise, i.e. before and after the test, and continuously throughout the braking process. The article presents the methodology of thermal imaging research and the preparation of the camera for outdoor research with objects with different emissivity. Due to the rotating brake disc, it was decided to measure using an IR camera because measurements using thermocouples were very difficult and complex. In exceptional situations, temperature measurement using thermocouples is used, but it requires an extensive additional measurement system and signal recording, which is more expensive. Correct configuration of the IR camera to real conditions is extremely important because it directly translates into the increase in measurement error.

Pages (from - to)

161 - 168

DOI

10.19206/CE-174320

URL

https://www.combustion-engines.eu/Thermal-imaging-of-the-disc-brake-and-drive-train-in-an-electric-locomotive-in-field,174320,0,2.html

License type

CC BY (attribution alone)

Open Access Mode

open journal