Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Problems of operation of positive pressure ventilators on the basis of surveys of Polish officers of the State Fire Service

Authors

[ 1 ] Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ 2 ] Instytut Konstrukcji Maszyn, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ SzD ] doctoral school student | [ P ] employee

Scientific discipline (Law 2.0)

[2.9] Mechanical engineering

Year of publication

2024

Published in

Scientific Reports

Journal year: 2024 | Journal volume: vol. 14

Article type

scientific article

Publication language

english

Keywords
EN
  • noise
  • exhaust emissions
  • occupational safety
  • firefighter
  • building smoke ventilation
  • positive pressure ventilation (PPV)
  • fire protection units
  • survey
Abstract

EN Positive pressure ventilators (PPV) used by 97.7% of officers of the National Fire Service in Poland, are characterized by work that is not in line with the expectations of the firefighters. In order to improve the technical and operational features of these devices, a survey was conducted among 25,000 eligible firefighters, identifying the application of these devices, problems in use and expected development directions. A total of 682 officers voluntarily completed the survey. Based on their findings, it was determined that ventilators are most often used to smoke out buildings after or during a fire. Mentioned problems when using these devices were mainly noise (78.2%), exhaust emissions (68.5%), and impediments to mobility through the device’s relatively heavy weight (40.2%). Other inconveniences were mentioned by less than 20% of firefighters. Polish firefighters expect the development of these devices mainly in terms of the above-mentioned features (noise reduction (81.7%) and reduction of the weight and size of the ventilators (about 50%)). Other expectations relate to the improvement of smoke removal in buildings: increasing the efficiency of smoke removal (46.4%) and efficiency regarding the rate of smoke removal in a building by increasing the size of the incoming airflow from the building’s surroundings (33.2%). About 15% of firefighters expect changes in the operation of the ventilator itself, that is, an increase in the effective operating time (electric ventilators) and an increase in the device’s uptime. The aim of the article is to identify the issues encountered during the operation and to indicate the expected direction of development for PPV by users. This information can be used by engineers to initiate new development work on these devices.

Pages (from - to)

10795-1 - 10795-12

DOI

10.1038/s41598-024-61507-3

URL

https://www.nature.com/articles/s41598-024-61507-3

Comments

Article number: 10795

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

140

Impact Factor

3,8 [List 2023]

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.