Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Chapter

Download BibTeX

Title

CFD investigation of the intensity of heat transfer at forced convection of preheated air in a steel pipe

Authors

[ 1 ] Instytut Konstrukcji Maszyn, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.9] Mechanical engineering

Year of publication

2024

Chapter type

chapter in monograph

Publication language

english

Keywords
EN
  • simulation study
  • air
  • steel pipe
  • heat transfer intensity
  • external heat convection coefficient
  • overall heat transfer coefficient
Abstract

EN This paper presents a CFD investigation in ABAQUS of the heat exchange intensity in curvilinear and linear zones of a steel pipe through which preheated air is flowing. The process intensity has been compared based on the average cross-section temperature differences. The research has been implemented as a continuation of a simulation study of the heat convection process in the pipe, as a result of which the temperature distribution of the fluid has been obtained, and the internal coefficient of convection heat exchange has been calculated. The external coefficient of convection heat exchange and the coefficient of overall heat exchange have been determined by ignoring the thermal resistance of the pipe wall. Heat exchange processes realized at three fluid velocities have been investigated. The impact of the fluid velocity on the intensity of the heat transfer process in the initial curvilinear zone of the pipe, on the values of the outer coefficient of heat convection and on the overall heat exchange coefficient, have been investigated. It has been found that the total decrease in velocity of 18.98 % resulting in a decrease in the ratio of temperature differences in the two zones by 8.21 %. In the first range of speed change, 6.16 % decrease in velocity leads to 6.04 % raise in the external heat convection coefficient and 2.30 % raise in the coefficient of overall heat exchange. In the second velocity range, 13.66 % decrease in velocity results in 16.72 % decrease in the external heat convection coefficient and 14.79 % decrease in the overall heat transfer coefficient.

Pages (from - to)

1 - 6

DOI

10.1109/EEAE60309.2024.10600561

URL

https://ieeexplore.ieee.org/document/10600561

Book

2024 9th International Conference on Energy Efficiency and Agricultural Engineering (EE&AE). Conference Proceedings

Presented on

9th International Conference on Energy Efficiency and Agricultural Engineering, EE&AE 2024, 27-29.06.2024, Ruse, Bulgaria

Ministry points / chapter

20

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.