Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Effect of Air Purifier Use in the Classrooms on Indoor Air Quality - Case Study

Authors

[ 1 ] Instytut Inżynierii Środowiska i Instalacji Budowlanych, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Year of publication

2021

Published in

Atmosphere

Journal year: 2021 | Journal volume: vol. 12 | Journal number: no. 12

Article type

scientific article

Publication language

english

Keywords
EN
  • indoor air quality (IAQ)
  • school
  • air purifier device
  • air purification
  • microbiological contamination
  • particulate matter
Abstract

EN Dissatisfaction with indoor air quality is common even in relatively new or renovated Polish school buildings. To improve air quality in educational buildings, portable devices have seen increased use, for which manufacturers guarantee a high level of indoor air purification. However, their optimized operation largely depends on their correct use. The aim of this article was to determine the effectiveness of air purification in a primary school using an air purification device with an analysis of the classroom indoor air quality (IAQ). Two criteria were used, microbiological and particulate matter concentration. Measurements were made before device installation and during its continuous operation, and before and after lessons on chosen days. Measurements related to IAQ did not detect clear differences in the analyzed measurement periods. For microbiological contamination, in the morning before lessons, the total count for all bacteria and microscopic fungi was definitely lower than after lessons. Comparing the periods before and after device installation, no clear tendency for reducing the bacteria count or microscopic fungi occurred during air purifier operation, nor was there any noticeable trend in the reduction of particulate matter. There was no improvement in air quality in the classrooms during the operation of the purification devices.

Date of online publication

30.11.2021

Pages (from - to)

1606-1 - 1606-14

DOI

10.3390/atmos12121606

URL

https://www.mdpi.com/2073-4433/12/12/1606

Comments

Article Number: 1606

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

70

Ministry points / journal in years 2017-2021

70

Impact Factor

3,11

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.