Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Determination of the Optimal Level of Reactive Power Compensation That Minimizes the Costs of Losses in Distribution Networks

Authors

[ 1 ] Instytut Elektroenergetyki, Wydział Inżynierii Środowiska i Energetyki, Politechnika Poznańska | [ P ] employee

Scientific discipline (Law 2.0)

[2.10] Environmental engineering, mining and energy

Year of publication

2024

Published in

Energies

Journal year: 2024 | Journal volume: vol. 17 | Journal number: iss. 1

Article type

scientific article

Publication language

english

Keywords
EN
  • distribution network
  • energy losses
  • reactive energy
  • reactive power compensation
Abstract

EN The objective of the presented paper is to verify economically justified levels of reactive energy compensation in the distribution network in the new market conditions, including the extensive use of smart metering systems, new types of load, or distributed generation. The proposed methodology is based on the minimization of annual costs of losses caused by the flow of reactive energy to the supplied loads through the equivalent resistance of the distribution system determined on the basis of statistical energy losses in this network. The costs of losses are compared to the costs of using compensating devices expressed by the levelized costs of reactive energy generation. The results are the relations describing the optimal annual average value of the tgφ factor to be maintained by customers to optimize the cost of loss of the distribution network caused by reactive energy flows. The dependence of the optimal tgφ value on the analyzed load and network parameters is also discussed. The resulting optimal tgφ levels should be considered in the tariffication process of services offered by distribution system operators to improve capacity and limit the costs of power network operation due to reactive energy transmission.

Pages (from - to)

150-1 - 150-24

DOI

10.3390/en17010150

URL

https://www.mdpi.com/1996-1073/17/1/150

Comments

Article number: 150

License type

CC BY (attribution alone)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

140

Impact Factor

3 [List 2023]