Research on the distribution of axial excitation of positive pressure ventilators in the aspect of stability safety of the load-bearing frame
[ 1 ] Instytut Konstrukcji Maszyn, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ 2 ] Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ 3 ] Instytut Architektury i Planowania Przestrzennego, Wydział Architektury, Politechnika Poznańska | [ P ] pracownik | [ SzD ] doktorant ze Szkoły Doktorskiej
[2.1] Architektura i urbanistyka[2.9] Inżynieria mechaniczna
2024
artykuł naukowy
angielski
- positive pressure ventilators
- rescue operation
- machine vibration
- vibration of internal combustion engine
- vibration of electric drive
- occupational safety
EN Positive pressure ventilators are exposed to self-shifting during their operation. The aim of the article was to perform research analysing dynamic excitations resulting from vibrations caused by the operation of the drive system. The tests included four different fans, including one with an electric drive. The tests carried out made it possible to determine the effective RMS R value of vibrations, which is a maximum of 0.970 G, and the direction of the excitation relative to the vertical and horizontal axes. In addition, the values of vibration amplitudes on individual axes of the adopted reference system were determined. In this case, the highest values were measured on the vertical axes for combustion-powered ventilators (vibration value from 20 to 35 m/s2 ) and in the axis along the fan rotor for electric-powered ventilators (vibration value from 1.1 m/s2).
15.01.2024
142 - 154
CC BY (uznanie autorstwa)
otwarte czasopismo
ostateczna wersja opublikowana
w momencie opublikowania
publiczny
100
1 [Lista 2023]