Depending on the amount of data to process, file generation may take longer.

If it takes too long to generate, you can limit the data by, for example, reducing the range of years.

Article

Download file Download BibTeX

Title

Strength analysis of critical components of high-pressure fuel pump with hypocycloid drive

Authors

[ 1 ] Instytut Silników Spalinowych i Napędów, Wydział Inżynierii Lądowej i Transportu, Politechnika Poznańska | [ 2 ] Instytut Konstrukcji Maszyn, Wydział Inżynierii Mechanicznej, Politechnika Poznańska | [ P ] employee | [ D ] phd student

Scientific discipline (Law 2.0)

[2.7] Civil engineering and transport
[2.9] Mechanical engineering

Year of publication

2020

Published in

Bulletin of the Polish Academy of Sciences. Technical Sciences

Journal year: 2020 | Journal volume: vol. 68 | Journal number: no. 6

Article type

scientific article

Publication language

english

Keywords
EN
  • strength analysis
  • FEM
  • high-pressure pump
  • pump with hypocycloid drive
  • fuel injection systems
Abstract

EN Most high-pressure fuel pumps for compression-ignition engines manufactured today are cam driven. These pumps have numerous advantages, such as low energy consumption and limited production costs. However, a problem arising from the nature of the cam mechanism is an unfavorable distribution of forces in the camshaft-plunger-cylinder system of a delivery section. The authors have proposed an innovative pump design that eliminates most of the problems present in conventional solutions. The pump utilizes a gear-based hypocycloid drive. This paper focuses mainly on the strength analysis of the two critical components (countershaft and mount) of the subassembly under the highest load – simulations were carried out for different critical load states. The following procedure of estimating fatigue life was adopted for computations: the operational evolution of stresses will be systematized to the set of amplitude stresses and mean stresses by means of the “Rainflow” method. The results obtained in the work showed that the main factor determining change of stresses was the presence of clearances in the pump mechanism. It has been proved that the values of clearances have a negative influence on the power transmission in particular – their presence results in loads being carried by the countershaft and not by the support inter-operating with it. This may cause frictional wear of teeth, leading to the improper operation of the transmission. The analysis showed that the mount was designed correctly. This facilitates the use of less demanding constructional materials.

Pages (from - to)

1341 - 1350

DOI

10.24425/bpasts.2020.135380

URL

http://www.czasopisma.pan.pl/dlibra/publication/135380/edition/118358/content

License type

CC BY-NC-ND (attribution - noncommercial - no derivatives)

Open Access Mode

open journal

Open Access Text Version

final published version

Date of Open Access to the publication

at the time of publication

Full text of article

Download file

Access level to full text

public

Ministry points / journal

100

Ministry points / journal in years 2017-2021

100

Impact Factor

1,662

This website uses cookies to remember the authenticated session of the user. For more information, read about Cookies and Privacy Policy.